The TP TRIAD is a unique approach to pumping dirty water and uses three (or four) open impeller pumps coupled in series to provide a high capacity pumping system capable of handling dirty water containing suspended solids up to 10mm in diameter. This ability to handle particles in thick suspension means that the TRIAD can pump from a multi-chamber settlement tank or even directly from a strainer box without the need for a fine filter screen and is therefore virtually maintenance free.
The TRIAD can operate multiple static sprinklers or a mobile irrigator.
Unlike many other pumping systems the P3 TRIAD requires an operating current of only 15 amps (20 amps for P4).
The TRIAD is a self-comtained,
ready to operate system mounted in a galvanised steel chassis with its own
weather-proof housing and automatic frost protection.
The unit is supplied complete with suction pipe,float switch and flexible
outlet pipe and fitted with all necessary electrical controls (including mains
isolating switch, earth leakage circuit breaker, MCB fuses and current overload
protection) built into a water-proof control housing.
An automatic flow-monitoring (AFM) system constantly checks the outlet flow and operates a warning light should a fault occur. If an inlet or outlet pipe or sprinkler becomes frozen up or blocked the AFM also switches off the pumps after a timed period to prevent damage to the motors.
The multi pump configuration provides a valuable emergency back-up facility as the unit can continue to operate should a fault occur on one of the pumps.
Since its introduction in 1989 the TRIAD system has been well tested and proved in operation on a wide variety of farms and our many customers can testify to its reliability and very low maintenance costs.
The system has been constantly upgraded to utilise improved technology and keep pace with current safety requirements.
|
SIMPLE INSTALLATION |
Complete ready to operate system; just connect to outlet pipe and electricity supply. |
|
SOLIDS HANDLING |
Can handle water containing particles in thick suspension. |
|
LOW MAINTENANCE |
No filter to clean. Designed for simple low cost servicing. |
|
LOW POWER REQUIREMENTS |
Only 15 amps (20 amps for 4 pump model). |
|
AUTOMATIC POWER RECOVERY |
Following an interruption to the power supply the system switches back on automatically. No manual reset is necessary. |
|
SAFETY WARNING SYSTEM |
Automatic Flow Monitor (AFM) constantly checks outlet flow & lights warning light if a fault occurs. |
|
AUTOMATIC FROST PROTECTION |
Heater unit is automatically switched on when temperature drops to danger level. AFM switches off pumps if sprinkler or pipes freeze up. |
|
EMERGENCY BACKUP |
In the event of a fault on one pump or motor unit the others can continue pumping while repairs are effected, or a stand-by pump unit can be fitted in a matter of minutes. |
|
EXPANDABLE SYSTEM |
Pressure/flow can be increased to meet expanding demand by adding an additional pump. |

| P3 - 3 PUMP MODEL | Gallons per Hour (Approx) |
| HEAD TO SPRINKLER | |
| 30ft (Single Sprinkler) | 1400 |
| 30ft (Two Sprinklers) | 2000 |
| 60ft (Single Sprinkler) | 1200 |
|
Max
Pressure 5.5bar
|
|
|
Max
head for sprinkler operation 70ft
|
|
| P4 - 4 PUMP MODEL | Gallons per Hour (Approx) |
| HEAD TO SPRINKLER | |
| 60ft (Single Sprinkler) | 1400 |
| 60ft (Two Sprinklers) | 2000 |
| 100ft (Single Sprinkler) | 1200 |
|
Max
Pressure 7bar
|
|
|
Max
head for sprinkler operation 120ft
|
|
3 X 1HP SERIALLY CONNECTED OPEN IMPELLER PUMPS Mounted in galvanised steel chassis with its own housing.
Complete with all plumbing and electrical fittings as follows:
| Suction hose | with non-return valve, 10mm screen & couplings. |
| Automatic flow monitor | switches off pumps if inlet pipe, outlet pipe or spinkler is frozen or blocked. |
| Emergency warning light | Operated by AFM and motor starter relay: lights if flow stops or if any of the motor units overload. |
| Float switch | carries low signal current to operate solenoid starter. |
| Pressure gauge. | |
| Main outlet valve. | |
| Flexible outlet hose with coupling to alkathene main. | |
| Bypass valve | can also be used for
direct attachment of sprinkler lead. |
| Anti-syphon valve. | |
| Quick release priming valve. | |
| Waterproof control
panel fitted with external 2 pole mains isolator switch & containing:- |
RCCB earth leakage
trip MCB fuses Solenoid motor starters Current overload cut-outs and timer relay. Indicator lights. |
| Heater and frost-stat | |
| Power requirement:- 15 amps (20 amps for 4 pump model). |
The P3 can be upgraded to a P4 at any time to cater for increased performance.
|
Sprinkler
system with heavy duty galvanised sled
|
|
Hydrant
unit with isolating valve and quick release coupling
|
|
50
mtrs 1 Tricoflex flying lead Strong, high pressure, lightweight
hose complete with quick release couplings
|
|
TRIAD
4 PUMP MODEL
|
<Last updated: 18 July 2002>
|
|
We have moved, please take down our new contact details!
Email:
sales@tppumps.co.uk
Tel: 01769 579487 Fax: 01769 574600
T P Pumps Ltd, Pathfields Business Park, South Molton, Devon, EX36 3LH, UK.